Canon products are known for their advanced, innovative features. Whether you have a Canon product or one without specific driver software, we have an ideal solution available here from https://dnasofts.com/. For wireless settings and attributes, the Download Centre is your first stop to check out Canon BJC-55 firmwares, drivers, softwares and Canon BJC-55 user manuals or others more .
BJC-55 printer is best suited for office use and its bundled with many features which makes it a productive and efficient machine. This product supports duplex printing and many other advanced features.

Canon BJC-55 Driver, Firmware and Manuals for Windows and MacOS

Get Epson printer driver, firmware and manual more over here: https://dnasofts.com/

Canon BJC-55 Driver

- Canon BJC-55 printer driver is a great way to stay up-to date with your office's printing devices! You can monitor the warning signs that an ink cartridge needs changing, check out any errors during scanning photos from one side onto paper produced by another (blurred), and more.
- So, what's the point? It <b/>won't let them hack into Computer Utilities & Cracking Tools Resets Chips
- With all these hackers out there who can access any WIC utility tool reset chip or crack adjustment program that you may have. The best way would be via purchasing a license key from https://nguyendangnam.com/ so they only get their hands on those printer drivers which allow us to fix 'paper jam' issues in our printers!

Download Canon BJC-55 Driver for Windows:

- Download Canon BJC-55 Driver for Windows 11: DOWNLOAD LINK

- Download Canon BJC-55 Driver for Windows 10 64bit: DOWNLOAD LINK

- Download Canon BJC-55 Driver for Windows 10 32bit: DOWNLOAD LINK

- Download Canon BJC-55 Driver for Windows 8 64bit: DOWNLOAD LINK

- Download Canon BJC-55 Driver for Windows 8 32bit: DOWNLOAD LINK

- Download Canon BJC-55 Driver for Windows 7 64bit: DOWNLOAD LINK

- Download Canon BJC-55 Driver for Windows 7 32bit: DOWNLOAD LINK

Download Canon BJC-55 printer Driver for Mac OS:

- Download Canon BJC-55 Driver for Mac OS 11.xx: DOWNLOAD LINK

- Download Canon BJC-55 Driver for Mac OS 10.xx: DOWNLOAD LINK

How to download softwares or documents of Canon BJC-55

STEP 1: Go to our website and search for "Canon BJC-55 driver, firmware, manual"

STEP 2: Choose your specific Canon BJC-55 driver, firmware and manual and click to Download button image

STEP 3: Wait for the downloading webpage and download the software

Canon BJC-55 driver, firmware, manual downloading webpage

STEP 4: Your downloaded file has been located in Browser Downloaded Page

Canon BJC-55 driver, firmware, manual downloaded file

STEP 5: Read the instructions to install and start using the softwares.

Canon BJC-55 Firmware

- The Canon BJC-55 printer Firmware is an intermediary software developed by Canon company, which helps to interact between the computer and hardware with each other. It's used when printing from a computer or sending jobs over WiFi Direct/Ethernet direct connection.
- For this reason the Canon BJC-55 printer need be refilled using original firmware in case components become unstable due technical error messages on screen about how to fix them; as well if you receive errors pertaining specifically within third party programs like Adobe Photoshop CS6 update manager crashing while trying install recent updates available online
- Canon BJC-55 original Firmware, also known simply by laymen’s terms “printer firmware." This intermediary software was developed by Epson company which helps interact between themselves an<br>

Download Original Canon BJC-55 Firmware for Windows:

- Original Canon BJC-55 Firmware for Windows: DOWNLOAD LINK

Download Canon BJC-55 Firmware for Mac OS:

- Original Canon BJC-55 Firmware for Mac OS: DOWNLOAD LINK

Canon BJC-55 User Manual

- Canon BJC-55 printer's User Manual is a valuable tool for any individual who purchases or rents one of their products. It contains information about basic assembly, maintenance procedures like changing ink cartridges as well as troubleshooting tips if you're having trouble with your new device and need some assistance from the manufacturer before calling customer service!
- With the Canon BJC-55 Manual, you can fix errors code or common problem like "printer is unresponsive" or "bad quality prints and slow scanning". You may also use this guide for following instructions on how to disassemble your Canon BJC-55 printer so that maintenance work becomes easy!

- Canon BJC-55 User Manuals for Windows: DOWNLOAD LINK

- Canon BJC-55 User Manuals for MacOS: DOWNLOAD LINK

[Quick guide] Fix Canon BJC-55 error code list

- Code: E001 0001
- Description: Fixing Main Thermistor high temperature detection error. The Fixing Main Thermistor in the Fixing Unit detected 284 deg C or higher for 0.2 sec or longer.
- Solutions: [Related parts] • Harnesses from the DC Controller PCB to the Fixing Thermistor 1. DC Controller PCB (UN04/J121) to Fixing Drawer (J1001DA) (Unit of replacement: FIXING DRAWER ASSEMBLY) 2. Fixing Drawer (J1001LA) to Relay Connector (8P) (Unit of replacement: CABLE, DRAWER RELAY) 3. Relay Connector (8P) to Fixing Thermistor (TH02) (Unit of replacement: FIXING FILM ASSEMBLY) • Harness between the DC Controller PCB (UN04/J115) and the Low Voltage Power Supply PCB (UN01/J322) (Unit of replacement: POWER SUPPLY ASSEMBLY) • Harness between the Low Voltage Power Supply PCB (UN01/J302) and the AC Interlock Switch (SW12) (Unit of replacement: CABLE, AC INTERLOCK SWITCH) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Solutions] 1. Check/replace the related harness/cable, connector and parts. 2. After performing the Solutions work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES


- Code: E001 0002
- Description: Fixing Sub Thermistor (Front) high temperature detection error. The Fixing Sub Thermistor (Front) in the Fixing Unit detected 295 deg C or higher for 0.2 sec or longer.
- Solutions: [Related parts] • Harnesses from the DC Controller PCB to the Fixing Thermistor 1. DC Controller PCB (UN04/J121) to Fixing Drawer (J1001DA) (Unit of replacement: FIXING DRAWER ASSEMBLY) 2. Fixing Drawer (J1001LA) to Relay Connector (8P) (Unit of replacement: CABLE, DRAWER RELAY) 3. Relay Connector (8P) to Fixing Thermistor (TH02) (Unit of replacement: FIXING FILM ASSEMBLY) • Harness between the DC Controller PCB (UN04/J115) and the Low Voltage Power Supply PCB (UN01/J322) (Unit of replacement: POWER SUPPLY ASSEMBLY) • Harness between the Low Voltage Power Supply PCB (UN01/J302) and the AC Interlock Switch (SW12) (Unit of replacement: CABLE, AC INTERLOCK SWITCH) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Solutions] 1. Check/replace the related harness/cable, connector and parts. 2. After performing the Solutions work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES


- Code: E002 0002
- Description: Fixing Sub Thermistor (Front) open circuit detection error. The Fixing Sub Thermistor (Front) detected a temperature of 40 deg C or lower for 3 sec or longer from when the Fixing Heater was turned ON until start of PI control
- Solutions: [Related parts] • Harnesses from the DC Controller PCB to the Fixing Thermistor 1. DC Controller PCB (UN04/J121) to Fixing Drawer (J1001DA) (Unit of replacement: FIXING DRAWER ASSEMBLY) 2. Fixing Drawer (J1001LA) to Relay Connector (8P) (Unit of replacement: CABLE, DRAWER RELAY) 3. Relay Connector (8P) to Fixing Thermistor (TH02) (Unit of replacement: FIXING FILM ASSEMBLY) • Harness between the DC Controller PCB (UN04/J115) and the Low Voltage Power Supply PCB (UN01/J322) (Unit of replacement: POWER SUPPLY ASSEMBLY) • Harness between the Low Voltage Power Supply PCB (UN01/J302) and the AC Interlock Switch (SW12) (Unit of replacement: CABLE, AC INTERLOCK SWITCH) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Solutions] 1. Check/replace the related harness/cable, connector and parts. 2. After performing the Solutions work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES


- Code: E002 0003
- Description: Fixing Sub Thermistor (Rear) open circuit detection error. The Fixing Sub Thermistor (Rear) detected a temperature of 40 deg C or lower for 3 sec or longer from when the Fixing Heater was turned ON until start of PI control.
- Solutions: [Related parts] • Harnesses from the DC Controller PCB to the Fixing Thermistor 1. DC Controller PCB (UN04/J121) to Fixing Drawer (J1001DA) (Unit of replacement: FIXING DRAWER ASSEMBLY) 2. Fixing Drawer (J1001LA) to Relay Connector (8P) (Unit of replacement: CABLE, DRAWER RELAY) 3. Relay Connector (8P) to Fixing Thermistor (TH02) (Unit of replacement: FIXING FILM ASSEMBLY) • Harness between the DC Controller PCB (UN04/J115) and the Low Voltage Power Supply PCB (UN01/J322) (Unit of replacement: POWER SUPPLY ASSEMBLY) • Harness between the Low Voltage Power Supply PCB (UN01/J302) and the AC Interlock Switch (SW12) (Unit of replacement: CABLE, AC INTERLOCK SWITCH) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Solutions] 1. Check/replace the related harness/cable, connector and parts. 2. After performing the Solutions work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES


- Code: E002 0004
- Description: Fixing Main Thermistor temperature increase detection error. The Fixing Main Thermistor detected a temperature increase of 1 deg C for less than 5 sec from when the Fixing Heater was turned ON until start of PI control.
- Solutions: [Related parts] • Harnesses from the DC Controller PCB to the Fixing Thermistor 1. DC Controller PCB (UN04/J121) to Fixing Drawer (J1001DA) (Unit of replacement: FIXING DRAWER ASSEMBLY) 2. Fixing Drawer (J1001LA) to Relay Connector (8P) (Unit of replacement: CABLE, DRAWER RELAY) 3. Relay Connector (8P) to Fixing Thermistor (TH02) (Unit of replacement: FIXING FILM ASSEMBLY) • Harness between the DC Controller PCB (UN04/J115) and the Low Voltage Power Supply PCB (UN01/J322) (Unit of replacement: POWER SUPPLY ASSEMBLY) • Harness between the Low Voltage Power Supply PCB (UN01/J302) and the AC Interlock Switch (SW12) (Unit of replacement: CABLE, AC INTERLOCK SWITCH) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Solutions] 1. Check/replace the related harness/cable, connector and parts. 2. After performing the Solutions work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES


- Code: E003 0004
- Description: Fixing Main Thermistor low temperature detection error.The Fixing Main Thermistor detected a temperature of 80 deg C or lower for 1 sec or longer from start of PI control until completion of the last rotation (the Fixing Heater was turned OFF).
- Solutions: [Related parts] • Harnesses from the DC Controller PCB to the Fixing Thermistor 1. DC Controller PCB (UN04/J121) to Fixing Drawer (J1001DA) (Unit of replacement: FIXING DRAWER ASSEMBLY) 2. Fixing Drawer (J1001LA) to Relay Connector (8P) (Unit of replacement: CABLE, DRAWER RELAY) 3. Relay Connector (8P) to Fixing Thermistor (TH02) (Unit of replacement: FIXING FILM ASSEMBLY) • Harness between the DC Controller PCB (UN04/J115) and the Low Voltage Power Supply PCB (UN01/J322) (Unit of replacement: POWER SUPPLY ASSEMBLY) • Harness between the Low Voltage Power Supply PCB (UN01/J302) and the AC Interlock Switch (SW12) (Unit of replacement: CABLE, AC INTERLOCK SWITCH) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Solutions] 1. Check/replace the related harness/cable, connector and parts. 2. After performing the Solutions work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

- Code: E003 0005
- Description: Fixing Sub Thermistor (Front) low temperature detection error. The Fixing Sub Thermistor (Front) detected a temperature of 80 deg C or lower for 1 sec or longer from start of PI control until completion of the last rotation (the Fixing Heater was turned OFF).
- Solutions: [Related parts] • Harnesses from the DC Controller PCB to the Fixing Thermistor 1. DC Controller PCB (UN04/J121) to Fixing Drawer (J1001DA) (Unit of replacement: FIXING DRAWER ASSEMBLY) 2. Fixing Drawer (J1001LA) to Relay Connector (8P) (Unit of replacement: CABLE, DRAWER RELAY) 3. Relay Connector (8P) to Fixing Thermistor (TH02) (Unit of replacement: FIXING FILM ASSEMBLY) • Harness between the DC Controller PCB (UN04/J115) and the Low Voltage Power Supply PCB (UN01/J322) (Unit of replacement: POWER SUPPLY ASSEMBLY) • Harness between the Low Voltage Power Supply PCB (UN01/J302) and the AC Interlock Switch (SW12) (Unit of replacement: CABLE, AC INTERLOCK SWITCH) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Solutions] 1. Check/replace the related harness/cable, connector and parts. 2. After performing the Solutions work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES


- Code: E003 0006
- Description: Fixing Sub Thermistor (Rear) low temperature detection error. The Fixing Sub Thermistor (Rear) detected a temperature of 80 deg C or lower for 1 sec or longer from start of PI control until completion of the last rotation (the Fixing Heater was turned OFF).
- Solutions: [Related parts] • Harnesses from the DC Controller PCB to the Fixing Thermistor 1. DC Controller PCB (UN04/J121) to Fixing Drawer (J1001DA) (Unit of replacement: FIXING DRAWER ASSEMBLY) 2. Fixing Drawer (J1001LA) to Relay Connector (8P) (Unit of replacement: CABLE, DRAWER RELAY) 3. Relay Connector (8P) to Fixing Thermistor (TH02) (Unit of replacement: FIXING FILM ASSEMBLY) • Harness between the DC Controller PCB (UN04/J115) and the Low Voltage Power Supply PCB (UN01/J322) (Unit of replacement: POWER SUPPLY ASSEMBLY) • Harness between the Low Voltage Power Supply PCB (UN01/J302) and the AC Interlock Switch (SW12) (Unit of replacement: CABLE, AC INTERLOCK SWITCH) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Solutions] 1. Check/replace the related harness/cable, connector and parts. 2. After performing the Solutions work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES


- Code: E004 0001
- Description: Fixing Relay welding detection error. Zero cross interruption was detected although the Fixing Relay was not turned ON.
- Solutions: [Related parts] • Harness from the DC Controller PCB (UN04/J115) and the Low Voltage Power Supply PCB (UN01/J322) (Unit of replacement: POWER SUPPLY ASSEMBLY) • Harness between the DC Controller PCB (UN04/J121) and the Fixing Drawer (J1001Demoticon (Unit of replacement: FIXING DRAWER ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Solutions] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES


- Code: E004 0002
- Description: Current detection circuit error. Current outside the specified range flowed to the Fixing Heater when the heater was turned ON. Or, failure of fixing current detection circuit was detected.
- Solutions: [Related parts] • Harnesses from the Low Voltage Power Supply PCB to the Fixing Heater 1. Low Voltage Power Supply PCB (UN01/J302) to AC Interlock Switch (SW12) (Unit of replacement: CABLE, AC INTERLOCK SWITCH) 2. AC Interlock Switch (SW12) to Fixing Drawer (J1001) (Unit of replacement: FIXING DRAWER ASSEMBLY) 3. Fixing Drawer (J1001) to Relay Connector (3P) (Unit of replacement: CABLE, DRAWER RELAY) 4. Relay Connector (3P) to Fixing Heater (H1 and H2/J1115) (Unit of replacement: FIXING FILM ASSEMBLY) • Harness between the DC Controller PCB (UN04/J121) and the Fixing Drawer (J1001Demoticon (Unit of replacement: FIXING DRAWER ASSEMBLY) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Solutions] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES


- Code: E009 0000
- Description: Fixing pressure timeout error. The Fixing Pressure Release Sensor did not detect ON status within 10 sec after the start of pressure application operation for fixing.
- Solutions: [Related parts] • Harnesses from the DC Controller PCB to the Fixing Pressure Release Sensor 1. DC Controller PCB (UN04/J122) to Relay Connector (11P) (Unit of replacement: CABLE, FEED) 2. Relay Connector (11P) to Fixing Pressure Release Sensor (PS13) (Unit of replacement: PAPER DELIVERY DRIVE ASSEMBLY) • Harnesses from the DC Controller PCB to the Fixing Motor 1. DC Controller PCB (UN04/J122) to Relay Connector (8P) (Unit of replacement: CABLE, FEED) 2. Relay Connector (8P) to Fixing Motor (M09) (Unit of replacement: FIXING DRIVE MOTOR ASSEMBLY) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Fixing Pressure Release Sensor (PS13) • Fixing Drive Unit (Unit of replacement: FIXING DRIVE ASSEMBLY) [Solutions] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES


- Code: E009 0001
- Description: Fixing disengagement timeout error. The Fixing Pressure Release Sensor did not detect OFF status within 10 sec after the start of fixing disengagement operation.
- Solutions: [Related parts] • Harnesses from the DC Controller PCB to the Fixing Pressure Release Sensor 1. DC Controller PCB (UN04/J122) to Relay Connector (11P) (Unit of replacement: CABLE, FEED) 2. Relay Connector (11P) to Fixing Pressure Release Sensor (PS13) (Unit of replacement: PAPER DELIVERY DRIVE ASSEMBLY) • Harnesses from the DC Controller PCB to the Fixing Motor 1. DC Controller PCB (UN04/J122) to Relay Connector (8P) (Unit of replacement: CABLE, FEED) 2. Relay Connector (8P) to Fixing Motor (M09) (Unit of replacement: FIXING DRIVE MOTOR ASSEMBLY) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Fixing Pressure Release Sensor (PS13) • Fixing Drive Unit (Unit of replacement: FIXING DRIVE ASSEMBLY) [Solutions] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Support fix printer solution and reset Canon BJC-55:
– Telegramhttps://t.me/hyperaktiv
– Facebookhttps://www.facebook.com/dngnm/

Related sources:
https://nguyendangnam.com/
https://shop.nguyendangnam.com
https://nguyendangnam.com/download-epson-artisan-710-driver-firmware-users-manual-and-wic-key.html
Fix other error code list about printer, https://nguyendangnam.com/epson-driver
Fix other error code list about printer, https://nguyendangnam.com/error-code
https://shop.nguyendangnam.com/product-category/adjustment-program/

Calendar

VIET NAM's Calendars